VIP Product Code: 120/1080
Product Description
Being installed after the steam trap, the sight checker is a device to be used for visually checking the conditions and leakage of steam traps. These sight checkers function as both sight glass and check valve. Connections are female screwed.
Specification
Maximum operating pressure: 10 Bar
Maximum operating temperature: 150°C
Use: Condensate pipes downstream steam traps
Connections: Female screwed ISO 7/1Rp(BS21)
Installation: Horizontal or vertical (bottom to top) installation
Sizes: 1/2" | 3/4" | 1" (other sizes may be available upon request)